System Operation
Settings
-
Press the MODE button to cycle to the next available System mode
-
Cycle through the modes until the desired System mode is displayed.
Available System modes vary with system settings.
System modes:
-
AUTO
-
HEAT
-
COOL
-
EM HEAT
-
OFF
Fan Operation Settings
-
Press the FAN button to cycle to the next available Fan mode
-
Cycle through the modes until the desired Fan mode is displayed
Available Fan modes vary with system settings.
Fan modes:
-
AUTO: Fan runs only when the heating or cooling system is on
-
ON: Fan is always on
-
CIRC: Fan runs about 33% of the time to circulate air.
Program Schedule
You can program four time periods each day, with different settings for weekdays and weekends. We recommend using the presets shown in the table at right; these presets are designed to reduce your heating/cooling expenses.
WAKE: Set to the time you wake up and your desired temperature during the morning until you leave for the day.
AWAY: Set to the time you leave home and your desired temperature while you are away (usually an energy-saving temperature).
HOME: Set to the time you return home and your desired evening temperature until bedtime.
SLEEP: Set to your bedtime and your desired overnight temperature (usually an energy-saving temperature).
Adjusting program schedules
-
Press MENU. Press
or
until SCHED is displayed.
-
A square appears around ON or OFF in the display. If you want to use a schedule, press
or
to select ON. Press Select to edit the schedule or press EXIT to exit the menu.
-
If editing the schedule, press SELECT to edit the day or days flashing in the display.
-
The word Wake should be flashing. Press NEXT. Press
or
to turn this schedule period on or off. Note that selecting Off will disable this schedule period. Press NEXT.
-
If the schedule period was set to ON, the time will be flashing. Press
or
to adjust the time for this period. Press NEXT.
-
The Heat setpoint will be flashing. Press
or
to adjust the Heat setpoint for this period. Press NEXT.
-
The Cool setpoint will be flashing. Press
or
to adjust the Cool setpoint for this period. Press NEXT.
-
The display will show the next schedule period flashing. Repeat steps 4 – 7 for the Away, Home and Sleep schedule settings. After completing all schedule settings for the day(s) selected, repeat these steps for the other days.
-
Press the SAVE & EXIT button at upper left.
When editing an existing schedule, you can advance to the setting you wish to change, edit that setting and press the SAVE & EXIT button to save changes.
Depending on what type of schedule the thermostat was set up for, days may be grouped or set individually.
Smart Response Feature
This feature allows the thermostat to “learn” how long the furnace and air conditioner take to reach programmed temperature settings, so the temperature is reached at the time you set. For example:
Set the Wake time to 6 am and the temperature to 70°. The heat will come on before 6 am, so the temperature is 70° by the time you wake at 6. The message “Active Recovery” is displayed when the system is activated before a scheduled time period.
Program schedule override (Temporary)
-
Press
or
to adjust the temperature.
-
Once at the desired setpoint temperature, no further action is needed. The new setpoint temperature will be held until the next scheduled time period begins.
-
Press the SAVE button or wait for the display to time out and return to the Home screen.
To cancel the Temporary Hold, press and release the HOLD button to cycle through the settings until CANCEL HOLD is selected.
Program schedule override (Permanent)
-
Press
or
to adjust the temperature.
-
Once at the desired setpoint temperature, press and release the HOLD button to cycle through the settings until HOLD PERMANENTLY is selected.
-
Press the SAVE button or wait for the display to time out and return to the Home screen.
To cancel the Permanent Hold, press and release the HOLD button to cycle through the settings until CANCEL HOLD is selected.
Built-In Compressor Protection
Damage can occur if your system’s compressor is restarted too soon after shutdown. This feature forces the compressor to wait for a few minutes before restarting. During the wait time, the display will show the message Waiting For Equipment under the room temperature reading.
When the safe wait time has elapsed, the message disappears, and the thermostat will show “Heat on” or “Cool on”.